Page 43 of 56
RAMP – Ramp Gain Adjustment
This command starts / stops the gain ramp on a specified channel. There is no query for this command!
ARGUMENT DETAILS
Name Type Size Values
Channel Channel 1 See GroupAndChannels
Group Group 1 2, 5, 7 (O, P, L)
Rate
Signed
Integer
1
-50 to +50 dB / s
If Rate = 0, the ramp will stop
If Rate < 0, the gain will ramp down
If Rate > 0, the gain will ramp up
Target
Signed
Integer
1
-65.00 to +20.00 dB
If NULL in text (0x80) in binary, the ramp will use the gain range as
the target.
TEXT FORM DETAILS
COMMAND FORM:DEVICE RAMP <Channel> <Group> <Rate> [Target]
REDIAL – Dial the last number again
This command redials the last number. There is no query for this command.
ARGUMENT DETAILS
Name Type Size Values
Channel Channel 1 See GroupAndChannels
Group Group 1 17 (R)
Reserved 2 0
TEXT FORM DETAILS
COMMAND FORM:DEVICE REDIAL <Channel>
REFSET – Reference Set
This command selects/reports the output a virtual reference uses for gain tracking.
ARGUMENT DETAILS
Name Type Size Values
Channel Channel 1 See GroupAndChannels
Group Group 1
20
(B)
Output Channel Channel 2 See 2 (O) in GroupAndChannels
TEXT FORM DETAILS
COMMAND FORM:DEVICE REFSET <Channel.> [Output]
RESET – Reset
Resets the unit. There is no query for this command.
TEXT FORM DETAILS
COMMAND FORM: DEVICE RESET